Charles SThe performance and reliability of Tecgen generator sets we purchased have been outstanding. They have seamlessly provided uninterrupted power supply during crucial times, ensuring the smooth operation of our business. Furthermore, your team's professionalism and dedication in assisting us throughout the purchasing process have been commendable.
-
Hannah GordonDear Tecgen, I would like to express my gratitude for the excellent genset you have provided. Our order of the Yandgong Genset have exceeded our expectations. The performance and reliability of Genset have been outstanding, ensuring uninterrupted power supply for our business. We are looking forward to continuing our partnership with Tecgen Genset.
6 Cylinder Soundproof Perkins Generator Set With Three Phase Output For Bank Use
Place of Origin | Fuzhou, China |
---|---|
Brand Name | Tecgen Power |
Certification | CE / SASO / SONCAP / COC / PVOC |
Model Number | TG165PS & TG220PS |
Minimum Order Quantity | 1 unit |
Price | Negotiation |
Packaging Details | Stretch film packaging |
Delivery Time | 7 - 15 Working Days |
Payment Terms | T/T, L/C |
Supply Ability | 200 Units Per Month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct | Perkins Diesel Generator | Type | Silent Type |
---|---|---|---|
Frequency | 50Hz | Output | 150kVA & 200kVA |
Engine Model | TG165PS 1106A-70TAG2 / TG220PS 1206A-E70TTAG1 | Aternator Brand | Stamford |
Engine Cylinder | 6 Cylinder | ||
Highlight | three phase output diesel generator,Perkins 6 cylinder diesel generator,Perkins diesel generator soundproof genset |
Perkins 6 cylinder diesel generator soundproof genset with three phase output for bank use
Standard Features:
Introducing our state-of-the-art Perkins 6 Cylinder Diesel Generator, a robust and reliable power solution tailored for your diverse needs. Available in two models, TG165PS and TG220PS, both are designed with soundproof enclosures to minimize noise pollution, making them ideal for Soundproof Genset applications. Both gensets operate at a frequency of 50Hz and offer a versatile voltage range of 415/240V, suitable for three-phase power distribution.
With prime power ratings of 120kW / 150kVA and 160kW / 200kVA respectively, these generators ensure continuous and stable power supply, even during peak loads. The standby power outputs are 132kW / 165kVA for TG165PS and 176kW / 220kVA for TG220PS, providing additional power reserves during emergencies.
Key Features:
- Engine Models: Equipped with powerful Perkins engines, 1106A-70TAG2 for TG165PS and 1206A-E70TTAG1 for TG220PS, both featuring indirect injection, turbocharging, and charge air cooling for optimal performance.
- Alternator Models: Stamford UCI 274F and UCI 274J alternators ensure high-efficiency power generation with rate outputs of 128kW and 184kW respectively.
- Controller System: The advanced DEIF SGC-420 controller offers comprehensive control functions, including AMF module, static auto battery charger, emergency stop push button, and ATS connection for seamless power management.
- Fuel Efficiency: Our gensets are designed for fuel efficiency, with fuel consumption rates starting from 9.1L/h at 25% load for TG165PS and 10.5L/h for TG220PS, ensuring cost-effective operation.
Perkins 6 Cylinder Diesel Generator Specifications:
Technical Specification: | |||
Perkins 6 Cylinder Diesel Generator Specification | |||
Genset Model | TG165PS | TG220PS | |
Silent | |||
Frequency | 50Hz | ||
Voltage | 415/240V | ||
Phase | Three Phase | ||
Rate Current | 208.7A | 278.2A | |
Prime Power | 120kW / 150kVA | 160kW / 200kVA | |
Standby Power | 132kW / 165kVA | 176kW / 220kVA | |
Engine Model | 1106A-70TAG2 | 1206A-E70TTAG1 | |
Alternator Model | UCI 274F | UCI 274J | |
Controller | DEIF SGC-420 | ||
Fuel Tank Capacity | 250L | 330L | |
Weight And Dimensions | |||
Length (mm) | 2900 | 3600 | |
width (mm) | 1100 | 1200 | |
Height (mm) | 1530 | 1700 | |
Weight (kgs) | 1930 | 2850 | |
Engine Specification | |||
Engine Model | 1106A-70TAG2 | 1206A-E70TTAG1 | |
Prime Power | 131kW | 176.8kW | |
Injection | Indirect | ||
Aspiration | Turbocharged and Charge Air Cooled | ||
No. of cylinders | 6 | ||
Bore of Stroke | 105x135mm | ||
Displacement | 7L | ||
Cooling | water | ||
Compression Ratio | 16:1 | 15.8:1 | |
Engine Oil capacity (L) | 16.5 | ||
Coolant Capacity ( In radiator) | 21 | ||
Governor | Electric | ||
Air Filter | Dry Element | ||
Fuel consumption | at 50Hz | at 50Hz | |
100% Load (L/h) | 33.4 | 42 | |
75% Load (L/h) | 24.7 | 31.4 | |
50% Load (L/h) | 16.4 | 21 | |
25% Load (L/h) | 9.1 | 10.5 | |
Alternator Specification | |||
Brand | Stamford | ||
Model | UCI 274F | UCI 274J | |
Rate Output | 128kW | 184kW | |
Pole | 4 | ||
Winding Connections | Star | ||
Insulation Class | H | ||
Enclosure | IP23 | ||
Altitude (m) | ≤1000 | ||
Voltage Regulator | AVR | ||
Steady State Voltage Regulator | 1% | ||
Bearing | single | ||
Controller System | |||
Brand | DEIF | ||
Model | SGC-420 | ||
Functions | Control with AMF module | ||
Static with auto. battery charger | |||
Emergency stop push button | |||
ATS Connection | |||
OPTIONAL EQUIPMENTS | |||
ATS Box, Switch Box, Remote Control, Daily Fuel Tank, Engine Heater, Water Heater, PMG Generator, Parallel Panel, Fuel-water separator, Trailer Type, 3000Hours Spare Parts |
Usage:
The Perkins 6 Cylinder Diesel Generator is perfect for a wide range of applications, including commercial buildings, hospitals, data centers, and industrial facilities. Its soundproof design makes it an excellent choice for residential areas and noise-sensitive environments. Whether you need a primary or backup power source, our gensets deliver reliable and consistent performance.
Advantages:
- Reliability: Built with high-quality components and rigorous testing, our gensets ensure long-lasting durability and minimal maintenance.
- Soundproof Design: The soundproof enclosure significantly reduces noise levels, making it suitable for use in noise-sensitive areas.
- Fuel Efficiency: Optimized engine performance and fuel consumption rates help reduce operational costs.
- Easy Maintenance: Designed for easy access to critical components, facilitating quick and efficient maintenance.
- Versatile Power Output: Suitable for a variety of load requirements, from prime to standby power.
Options:
Upgrade your Perkins 6 Cylinder Diesel Generator with a range of optional equipment, including:
- ATS Box: Automatic Transfer Switch for seamless power transfer between main and generator sources.
- Remote Control: Monitor and control your genset remotely via a user-friendly interface.
- Daily Fuel Tank: Additional fuel storage for extended operation without refueling.
- Engine and Water Heaters: Ensure optimal engine performance in cold climates.
- PMG Generator: Provides power for excitation and control systems, enhancing generator efficiency.
- Parallel Panel: Allows for the connection of multiple gensets to operate in parallel, increasing overall power capacity.
- Fuel-Water Separator: Protects your engine from water contamination in fuel.
- Trailer Type: Mobile genset solutions for on-site power needs.
- 3000 Hours Spare Parts: Ensure you're always prepared with a kit of essential spare parts for up to 3000 hours of operation.
FAQs:
Q: What is the noise level of the Perkins 6 Cylinder Diesel Generator?
A: Our gensets are designed with soundproof enclosures to minimize noise pollution, making them suitable for noise-sensitive environments.
Q: How fuel-efficient are these generators?
A: Our gensets are optimized for fuel efficiency, with low fuel consumption rates at various load levels.
Q: Can I monitor and control the generator remotely?
A: Yes, with the optional Remote Control upgrade, you can monitor and control your genset remotely via a user-friendly interface.
By choosing our Perkins 6 Cylinder Diesel Generator, you're investing in a reliable, fuel-efficient, and soundproof power solution tailored to meet your specific needs. Contact us today for more information and to discuss your power generation requirements.